Silex technology Embedded Intelligent Module SX-560 Specifikace Strana 92

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 104
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 91
Table 40 TCP/IP Commands
Command
Description
SET IP MEthod
Sets method of getting IP address
The default value is Auto.
Format:
SET IP MEthod [ AUTO | DHCP | STATIC ]
SET IP REtry
Enables or disables LPD retry on incomplete job
The default value is Disable.
Format:
SET IP REtry [ENable | DIsable]
SET IP ROuter
Sets default router address
The default value is 0.0.0.0.
Format:
SET IP ROuter aa.bb.cc.dd
SET IP SUbnet
Sets IP subnet mask
The default value is 0.0.0.0.
Format:
SET IP SUbnet aa.bb.cc.dd
SET IP TCP
Enables or disables the raw TCP 9100 protocol
The default value is Enable.
Format:
SET IP TCP [ENable | DIsable]
SET IP TELnet
Enables or disables Telnet protocol
The default value is Enable.
Format:
SET IP TELnet [ENable | DIsable]
SET IP TFTP
Enables or disables TFTP protocol
The default value is Enable.
Format:
SET IP TFTP [ENable | DIsable ]
SET IP TImeout
Sets TCP inactivity timeout.
If fast timeout is enabled, the timeout is calculated as seconds.
If fast timeout is disabled, the timeout is calculated as minutes.
The default value is 1 minute.
Format:
SET IP Timeout n